Product Data Sheet 6314 N/2TDHHP
02/01/2019 page 6 of 15
3.2 Electrical Operating Data
Measurement
conditions:
Normal air density = 1,2 kg/m3; Temperature 23°C +/ - 3°C; Motor axis horizontal; warm-up
time before measuring 5 minutes (unless otherwise specified). In the intake and outlet area
should not be any solid obstruction within 0,5 m.
∆p = 0:
corresp. to free air flow (see chapter aerodynamics)
I:
corresp. to arithm. mean current value
Name Condition
PWM 0001 PWM: 95 %; f: 2 kHz
>90% PWM; f = 2 kHz or broken lead wire (open control input)
Features Condition Symbol Values
Voltage range U 16 V 36,0 V
Nominal voltage U
N
24,0 V
Power consumption 69 W 156 W 158 W
+- 10 % +- 10 % +- 10 %
Tolerance
∆p = 0
PWM 0010
P
Current consumption 4.300 mA 6.500 mA 4.400 mA
+- 10 % +- 10 % +- 10 %
Tolerance
∆p = 0
PWM 0010
I
Speed 5.600 1/min 7.200 1/min 7.200 1/min
+- 5 % +- 2 % +- 2 %
Tolerance
∆p = 0
PWM 0010
n