Datasheet

Product Data Sheet 6314 H
02/02/2019 page 5 of 14
3 Operating Data
3.1 Electrical Operating Data
Measurement
conditions:
Normal air density = 1,2 kg/m3; Temperature 23°C +/ - 3°C; Motor axis horizontal; warm-up
time before measuring 5 minutes (unless otherwise specified). In the intake and outlet area
should not be any solid obstruction within 0,5 m.
p = 0:
corresp. to free air flow (see chapter aerodynamics)
I:
corresp. to arithm. mean current value
Note:
No inrush current at Unom means:
The internal electrolytic capacitor 470uF/35V has no resistor or inrush current limitation, essentially the power supply
and the type and length of the connecting cable is limiting the Inrush current.
Features Condition Symbol Values
Voltage range U 16,0 V 30,0 V
Nominal voltage U
N
24,0 V
Power consumption 16,5 W 30 W 32 W
+- 15 % +- 10 % +- 10 %
Tolerance
p = 0
0010
P
Current consumption 1.040 mA 1.250 mA 1.050 mA
+- 15 % +- 10 % +- 10 %
Tolerance
p = 0
0010
I
Speed 3.900 1/min 5.000 1/min 5.000 1/min
+- 10 % +- 5 % +- 5 %
Tolerance
p = 0
0010
n
Starting current
consumption
1.900 mA
3.2 Electrical Features
Electronic function Speed-Controlled
Reversed polarity protection Rectifying diode
Max. residual current at U
N
I
F
<= 5 mA
Locked rotor protection Auto restart
Locked rotor current at U
N
I
block
Clock signal at locked rotor
t
3
/ t
4
typical: 0,5 s / 7,0 s