Datasheet

Product Data Sheet 6314/2TDHHPU
02/01/2019 page 11 of 13
Please require severity levels and specification parameters from the responsible development departments.
4.3 EMC
Kind Radiated Emission; 30 MHz - 1000 MHz
According DIN EN 55032:2016-02
Ceck accuracy / Limit Class A
Result Below limit Class B
Kind Electrostatic Discharge Immunity Test
According DIN EN 61000-4-2:2001-12
Ceck accuracy / Limit Contact Discharge +/- 4 kV; Air Discharge +/- 8 kV
Result A: The monitored function operates as designed during and after exposure
to a disturbance.
Kind Electromagnetic Field Immunity Test
According DIN EN 61000-4-3:2006-12
Ceck accuracy / Limit 10 V/m; 80 - 1000 MHz; AM; m = 0,8; f = 1 kHz; 1%; t = 3 s
Result A: The monitored function operates as designed during and after exposure
to a disturbance.
Kind Electrical Fast Transient / Burst Immunity Test
According DIN EN 61000-4-4:2005-07
Ceck accuracy / Limit +/- 2 kV on Power Lines; Coupling: POS, NEG, {PE}, ALL, 5 kHz and 100
kHz; 1 min
Result A: The monitored function operates as designed during and after exposure
to a disturbance.
Kind Immunity to Conducted Disturbances, Induced by RF-Fields
According DIN EN 61000-4-6:2001-12
Ceck accuracy / Limit 10 Vrms; 150 kHz - 80 MHz; m = 0,8; f = 1 kHz; 1%; t = 3 s
Result A: The monitored function operates as designed during and after exposure
to a disturbance.