Datasheet

Product Data Sheet 6314/2MP
02/01/2019 page 5 of 12
0% - 7% PWM: 0 1/min
7% - 10% PWM: 700 1/min (corresponding to min. speed)
10% - 90% PWM: linear increasing curve
90% - 100% PWM: 3.700 1/min (corresponding to max. speed)
3.2 Electrical Operating Data
Measurement
conditions:
Normal air density = 1,2 kg/m3; Temperature 23°C +/ - 3°C; Motor axis horizontal; warm-up
time before measuring 5 minutes (unless otherwise specified). In the intake and outlet area
should not be any solid obstruction within 0,5 m.
∆p = 0:
corresp. to free air flow (see chapter aerodynamics)
I:
corresp. to arithm. mean current value
Name Condition
PWM 0001 PWM: 100 %; f: 2 kHz
Features Condition Symbol Values
Voltage range U 16 V 30 V
Nominal voltage U
N
24 V
Power consumption 6,1 W 14,2 W 15 W
+- 15 % +- 20 % +- 10 %
Tolerance
∆p = 0
PWM 0010
P
Current consumption 390 mA 590 mA 510 mA
+- 15 % +- 17,5 % +- 10 %
Tolerance
∆p = 0
PWM 0010
I
Speed 2.530 1/min 3.700 1/min 3.700 1/min
+- 10 % +- 10 % +- 5 %
Tolerance
∆p = 0
PWM 0010
n