Datasheet
Product Data Sheet 612 FH
01/31/2019 page 4 of 9
3 Operating Data
3.1 Electrical Operating Data
Measurement
conditions:
Normal air density = 1,2 kg/m3; Temperature 23°C +/ - 3°C; Motor axis horizontal; warm-up
time before measuring 5 minutes (unless otherwise specified). In the intake and outlet area
should not be any solid obstruction within 0,5 m.
∆p = 0:
corresp. to free air flow (see chapter aerodynamics)
I:
corresp. to arithm. mean current value
Features Condition Symbol Values
Voltage range U 10,0 V 13,2 V
Nominal voltage U
N
12,0 V
Power consumption 0,9 W 1,4 W 1,7 W
+- 17,5 % +- 12,5 % +- 17,5 %
Tolerance
∆p = 0
0010
P
Current consumption 95 mA 118 mA 125 mA
+- 17,5 % +- 12,5 % +- 17,5 %
Tolerance
∆p = 0
0010
I
Speed 3.900 1/min 4.500 1/min 4.800 1/min
+- 15,0 % +- 10,0 % +- 15,0 %
Tolerance
∆p = 0
0010
n
Starting current
consumption
200 mA
3.2 Electrical Features
Electronic function None
Reversed polarity protection Rectifying diode
Max. residual current at U
N
I
F
<= 30 nA
Locked rotor protection Auto restart
Locked rotor current at U
N
I
block
approx. 200 mA
Clock signal at locked rotor
t
3
/ t
4
typical: 0,06 s / 0,25 s