Datasheet

Product Data Sheet 4414 HU
02/01/2019 page 4 of 9
3 Operating Data
3.1 Electrical Operating Data
Measurement
conditions:
Normal air density = 1,2 kg/m3; Temperature 23°C +/ - 3°C; Motor axis horizontal; warm-up
time before measuring 5 minutes (unless otherwise specified). In the intake and outlet area
should not be any solid obstruction within 0,5 m.
p = 0:
corresp. to free air flow (see chapter aerodynamics)
I:
corresp. to arithm. mean current value
Features Condition Symbol Values
Voltage range U 12,0 V 27,6 V
Nominal voltage U
N
24,0 V
Power consumption 1,9 W 8,2 W 9,1 W
+- 17,5 % +- 25,0 % +- 25,0 %
Tolerance
p = 0
0010
P
Current consumption 157 mA 340 mA 330 mA
+- 17,5 % +- 25,0 % +- 25,0 %
Tolerance
p = 0
0010
I
Speed 2.460 1/min 4.300 1/min 4.300 1/min
+- 12,5 % +- 3,0 % +- 3,0 %
Tolerance
p = 0
0010
n
Starting current
consumption
< 2.300 mA
3.2 Electrical Features
Electronic function Speed-Controlled
Reversed polarity protection Rectifying diode
Max. residual current at U
N
I
F
<= 100 uA
Locked rotor protection Auto restart
Locked rotor current at U
N
I
block
approx. 2.150 mA
Clock signal at locked rotor
t
3
/ t
4
typical: 0,5 s / 10 s