Datasheet
Product Data Sheet 4318 N/2N
01/31/2019 page 4 of 12
3 Operating Data
3.1 Electrical Operating Data
Measurement
conditions:
Normal air density = 1,2 kg/m3; Temperature 23°C +/ - 3°C; Motor axis horizontal; warm-up
time before measuring 5 minutes (unless otherwise specified). In the intake and outlet area
should not be any solid obstruction within 0,5 m.
∆p = 0:
corresp. to free air flow (see chapter aerodynamics)
I:
corresp. to arithm. mean current value
Features Condition Symbol Values
Voltage range U 36 V 60 V
Nominal voltage U
N
48 V
Power consumption 2,3 W 4,3 W 6,9 W
+- 17,5 % +- 12,5 % +- 15 %
Tolerance
∆p = 0
0010
P
Current consumption 65 mA 90 mA 115 mA
+- 17,5 % +- 12,5 % +- 15 %
Tolerance
∆p = 0
0010
I
Speed 2.200 1/min 2.700 1/min 3.150 1/min
+- 12,5 % +- 7,5 % +- 10 %
Tolerance
∆p = 0
0010
n
Starting current
consumption
400 mA