Datasheet

Product Data Sheet 4314 NH3
02/01/2019 page 8 of 10
Axes of vibration 3
severity level
stationary use
1 storage /
transportation
Random vibration not in use
IEC 60068-2-64
Frequency range / ASD
G
RMS
Axes of vibration
Test duration
Random vibration
5 - 20 Hz : 1,0 / s³
20 - 500 Hz : - 3 dB / Oct
0,91 G
3
3 x 5 h
storage /
transportation
Bump not in use
IEC 60068-2-29
Shock spectrum
Acceleration
Duration
Number of bumps (+X, -X, -Y, +Y, -Z, +Z)
Total bumps
Bump
half sine
18 G
6 ms
100 in each direction
600
stationary use Random vibration in use
IEC 60068-2-64
Frequency range / ASD
G
RMS
Axes of vibration
Test duration
Random vibration
5 - 20 Hz : 2,0 m
2
/ s
3
20- 150 Hz : - 3 dB / Oct
0,83 G
3
3 x 5 h
stationary use Bump in use
IEC 60068-2-29
Shock spectrum
Acceleration
Duration
Number of bumps (+X, -X, -Y, +Y, -Z, +Z)
Total bumps
Bump
half sine
5 G
11 ms
100 in each direction
600
4.4 EMC
Kind Radiated Emission; 30 MHz - 1000 MHz
According DIN EN 55032:2016-02
Ceck accuracy / Limit Class B
Result Below limit Class B
Kind Electrical Fast Transient / Burst Immunity Test
According DIN EN 61000-4-4:2005-07
Ceck accuracy / Limit +/- 2 kV on Power Lines; Coupling: POS, NEG, {PE}, ALL, 5 kHz and 100
kHz; 1 min
Result A: The monitored function operates as designed during and after exposure
to a disturbance.