3.2 Electrical Operating Data
Measurement
conditions:
Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C; Motor axis horizontal; warm-up
time before measuring 5 minutes (unless otherwise specified). In the intake and outlet area
should not be any solid obstruction within 0,5 m.
p = 0:
corresp. to free air flow (see chapter aerodynamics)
I:
corresp. to arithm. mean current value
Name
TU 0001
NTC 0001 NTC <= 33 kOhm
Features
Symbol
Values
Voltage range U 8 V 15 V
Nominal voltage U
N
12 V
Power consumption p = 0
TU / NTC
0010
P
0,8 W 1,9 W 2,1 W
Tolerance
+- 17,5 % +- 25 % +- 25 %
Current consumption p = 0
TU / NTC
0010
I
100 mA 160 mA 138 mA
Tolerance
+- 17,5 % +- 25 % +- 25 %
Speed p = 0
TU / NTC
0010
n
1.470 1/min 2.100 1/min 2.100 1/min
Tolerance
+- 12,5 % +- 6 % +- 6 %
Starting current
consumption
780 mA
3.3 Electrical Features
Electronic function Speed-Controlled
Reversed polarity protection Rectifying diode
Max. residual current at U
N
I
F
< 100 uA
Locked rotor protection Auto restart
Locked rotor current at U
N
I
block
approx. 750 mA
Clock signal at locked rotor
t
3
/ t
4
typical: 1 s / 10 s