Datasheet

Product Data Sheet 422 J/2HP
06/28/2017 page 5 of 13
3.2 Electrical Operating Data
Measurement
conditions:
Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C; Motor axis horizontal; warm-up
time before measuring 5 minutes (unless otherwise specified). In the intake and outlet area
should not be any solid obstruction within 0,5 m.
p = 0:
corresp. to free air flow (see chapter aerodynamics)
I:
corresp. to arithm. mean current value
Name
PWM 0001 PWM: 100 %; f: 25 kHz
Features
Symbol
Values
Voltage range U 8,0 V 13,8 V
Nominal voltage U
N
12 V
Power consumption
p = 0
PWM 0010
P
3,2 W 6,9 W 9 W
Tolerance
+- 20 % +- 15 % +- 15 %
Current consumption
p = 0
PWM 0010
I
400 mA 575 mA 650 mA
Tolerance
+- 20 % +- 15 % +- 15 %
Speed
p = 0
PWM 0010
n
12.900 1/min 17.250 1/min 18.700 1/min
Tolerance
+- 15 % +- 10 % +- 10 %
Starting current
consumption
<= 1.800 mA