Datasheet

Product Data Sheet 422 J/2HP
06/28/2017 page 11 of 13
Test duration
3 x 30 min
storage /
transportation
Bump not in use
IEC 60068-2-29
Shock spectrum
Acceleration
Duration
Number of bumps (+X, -X, -Y, +Y, -Z, +Z)
Total bumps
Bump
half sine
18 G
6 ms
100 in each direction
600
stationary use Random vibration in use
IEC 60068-2-64
Frequency range / ASD
G
RMS
Axes of vibration
Test duration
Random vibration
5 - 10 Hz : +6 dB / Oct
10 - 50 Hz : 1,0 m
2
/ s
3
50 - 200 Hz : - 6 dB / Oct
0,65 G
3
3 x 30 min
stationary use Bump in use
IEC 60068-2-29
Shock spectrum
Acceleration
Duration
Number of bumps (+X, -X, -Y, +Y, -Z, +Z)
Total bumps
Bump
half sine
5 G
11 ms
100 in each direction
600