Datasheet

Product Data Sheet 412 J
07/10/2017 page 4 of 8
3 Operating Data
3.1 Electrical Operating Data
Measurement
conditions:
Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C; Motor axis horizontal; warm-up
time before measuring 5 minutes (unless otherwise specified). In the intake and outlet area
should not be any solid obstruction within 0,5 m.
p = 0:
corresp. to free air flow (see chapter aerodynamics)
I:
corresp. to arithm. mean current value
Features
Condition
Values
Voltage range U 8 V 14 V
Nominal voltage U
N
12 V
Power consumption
p = 0
0010
P
1 W 2,4 W 3 W
Tolerance
+- 20 % +- 20 % +- 20 %
Current consumption
p = 0
0010
I
130 mA 200 mA 225 mA
Tolerance
+- 20 % +- 20 % +- 20 %
Speed
p = 0
0010
n
6.850 1/min 10.300 1/min 11.700 1/min
Tolerance
+- 15 % +- 15 %
+ 10 % - 15 %
Starting current
consumption
1.300 mA
3.2 Electrical Features
Electronic function None
Reversed polarity protection Rectifying diode
Max. residual current at U
N
I
F
<= 50 uA
Locked rotor protection Auto restart
Locked rotor current at U
N
I
block
approx. 1.300 mA
Clock signal at locked rotor
t
3
/ t
4
typical: 0,16 s / 1,0 s