Datasheet
Product Data Sheet 4114 N/2H4P
02/01/2019 page 5 of 12
3.2 Electrical Operating Data
Measurement
conditions:
Normal air density = 1,2 kg/m3; Temperature 23°C +/ - 3°C; Motor axis horizontal; warm-up
time before measuring 5 minutes (unless otherwise specified). In the intake and outlet area
should not be any solid obstruction within 0,5 m.
∆p = 0:
corresp. to free air flow (see chapter aerodynamics)
I:
corresp. to arithm. mean current value
Name Condition
PWM 0001 PWM: 95 %; f: 2 kHz
Note:
No inrush current at Unom means:
The internal electrolytic capacitor 39uF/100V has no resistor or inrush current limitation, essentially the power supply
and the type and length of the connecting cable is limiting the Inrush current.
Features Condition Symbol Values
Voltage range U 16 V 30 V
Nominal voltage U
N
24 V
Power consumption 13,3 W 33,5 W 34,2 W
+- 15 % +- 10 % +- 10 %
Tolerance
∆p = 0
PWM 0010
P
Current consumption 830 mA 1.400 mA 1.140 mA
+- 15 % +- 10 % +- 10 %
Tolerance
∆p = 0
PWM 0010
I
Speed 5.100 1/min 6.800 1/min 6.800 1/min
+- 10 % +- 5 % +- 5 %
Tolerance
∆p = 0
PWM 0010
n
Starting current
consumption
2.200 mA