Datasheet
Product Data Sheet 4114 N/2H3P-309
02/01/2019 page 5 of 12
VCEmax. >12V
Isink max. >5mA
VCEsat <0,15V
3.2 Electrical Operating Data
Measurement
conditions:
Normal air density = 1,2 kg/m3; Temperature 23°C +/ - 3°C; Motor axis horizontal; warm-up
time before measuring 5 minutes (unless otherwise specified). In the intake and outlet area
should not be any solid obstruction within 0,5 m.
∆p = 0:
corresp. to free air flow (see chapter aerodynamics)
I:
corresp. to arithm. mean current value
Name Condition
PWM 0001 PWM: 100 %; f: 2 kHz
Note:
No inrush current at Unom means:
The internal electrolytic capacitor 120uF/50V has no resistor or inrush current limitation, essentially the type and length
of the connecting cable is limiting the Inrush current.
Features Condition Symbol Values
Voltage range U 16 V 30 V
Nominal voltage U
N
24 V
Power consumption 9 W 22 W 25,2 W
+- 15 % +- 10 % +- 10 %
Tolerance
∆p = 0
PWM 0010
P
Current consumption 560 mA 920 mA 840 mA
+- 15 % +- 10 % +- 10 %
Tolerance
∆p = 0
PWM 0010
I
Speed 4.300 1/min 6.000 1/min 6.000 1/min
+- 10 % +- 10,0 % +- 7,5 %
Tolerance
∆p = 0
PWM 0010
n
Starting current
consumption
<= 2.500 mA