Datasheet
Product Data Sheet 405 F/2H
01/31/2019 page 4 of 9
3 Operating Data
3.1 Electrical Operating Data
Measurement
conditions:
Normal air density = 1,2 kg/m3; Temperature 23°C +/ - 3°C; Motor axis horizontal; warm-up
time before measuring 5 minutes (unless otherwise specified). In the intake and outlet area
should not be any solid obstruction within 0,5 m.
∆p = 0:
corresp. to free air flow (see chapter aerodynamics)
I:
corresp. to arithm. mean current value
Features Condition Symbol Values
Voltage range U 4,5 V 5,5 V
Nominal voltage U
N
5,0 V
Power consumption 0,7 W 0,9 W 1,1 W
+- 17,5 % +- 12,5 % +- 17,5 %
Tolerance
∆p = 0
0010
P
Current consumption 160 mA 180 mA 200 mA
+- 17,5 % +- 12,5 % +- 17,5 %
Tolerance
∆p = 0
0010
I
Speed 5.200 1/min 6.000 1/min 6.600 1/min
+- 15,0 % +- 10,0 % +- 15,0 %
Tolerance
∆p = 0
0010
n
Starting current
consumption
400 mA