Datasheet
Product Data Sheet 3254 JH
02/01/2019 page 4 of 10
3 Operating Data
3.1 Electrical Operating Data
Measurement
conditions:
Normal air density = 1,2 kg/m3; Temperature 23°C +/ - 3°C; Motor axis horizontal; warm-up
time before measuring 5 minutes (unless otherwise specified). In the intake and outlet area
should not be any solid obstruction within 0,5 m.
∆p = 0:
corresp. to free air flow (see chapter aerodynamics)
I:
corresp. to arithm. mean current value
Features Condition Symbol Values
Voltage range U 14 V 26,4 V
Nominal voltage U
N
24 V
Power consumption 2,2 W 7 W 8,5 W
+- 20 % +- 15 % +- 15 %
Tolerance
∆p = 0
0010
P
Current consumption 157 mA 292 mA 322 mA
+- 20 % +- 15 % +- 20 %
Tolerance
∆p = 0
0010
I
Speed 2.550 1/min 4.100 1/min 4.400 1/min
+- 15 % +- 10 % +- 15 %
Tolerance
∆p = 0
0010
n
Starting current
consumption
<= 1.000 mA
3.2 Electrical Features
Electronic function Speed-Controlled
Reversed polarity protection Rectifying diode
Max. residual current at U
N
I
F
<= 200 uA
Locked rotor protection Auto restart
Locked rotor current at U
N
I
block
approx. 1.500 mA
Clock signal at locked rotor
t
3
/ t
4
typical: 1 s / 9 s
First pulse t5 typical 1,6s (1,3 .. 1,9s) followed by t4. Afterwards cyclical t3/t4.