Data Sheet

Product Data Sheet 3314 NN
01/31/2019 page 6 of 9
3.4 Sound Data
Measurement
conditions:
Sound pressure level: 1 meter distance between microphone and the air intake.
Sound power level: Acc. to DIN 45635 part 38 (ISO 10302)
Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 dB(A)
For further measurement conditions see chapter aerodynamics.
a.) Operation condition:
2.650 1/min at free air flow
Optimal operating point
69,0 m3/h @ 10 Pa
Sound power level at the optimal operating
point
4,7 bel(A)
Sound pressure level at free air flow,
measured in rubber bands
33,0 dB(A)
4 Environment
4.1 General
Min. permitted ambient temperature TU min.
-20 °C
Max. permitted ambient temperature TU max.
75 °C
Min. permitted storage temperature TL min.
-40 °C
Max. permitted storage temperature TL max.
80 °C
4.2 Climatic Requirements
Humidity requirements
humid heat, constant; according to DIN EN 60068-2-78, 14 days
Water exposure
None
Dust requirements
None
Salt fog requirements
None
Permitted application area:
The product is intended for use in sheltered rooms with controlled temperature and controlled humidity. Directly
exposure to water must be avoided.
Pollution degree 1 (according DIN EN 60664-1)
There is either no pollution or it occurs only dry, non-conductive pollution. The pollution has no negative impact.
4.3 Mechanical Requirements
severity level
Vibration (sinusoidal)
1 G
Vibration (sinusoidal) in use
IEC 60068-2-6
Displacement / frequency range
Acceleration / frequency range
Sweep rate
Sweep cycles
Duration
Vibration (sinusoidal)
0,075 mm / 10-58, 58-10 Hz
1 G / 58-500-58 Hz
1 Oct./min
10
2 hrs.