Data Sheet
Product Data Sheet 4484 F
02/01/2019 page 4 of 8
3 Operating Data
3.1 Electrical Operating Data
Measurement
conditions:
Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C; Motor axis horizontal; warm-up
time before measuring 5 minutes (unless otherwise specified). In the intake and outlet area
should not be any solid obstruction within 0,5 m.
∆p = 0:
corresp. to free air flow (see chapter aerodynamics)
I:
corresp. to arithm. mean current value
Features
Condition
Symbol
Values
Voltage range
U
12,0 V
28,0 V
Nominal voltage
U
N
24,0 V
Power consumption
∆p = 0
0010
P
1,1 W
5,0 W
7,0 W
Tolerance
+- 17,5 %
+- 12,5 %
+- 15,0 %
Current consumption
∆p = 0
0010
I
95 mA
210 mA
250 mA
Tolerance
+- 17,5 %
+- 12,5 %
+- 15,0 %
Speed
∆p = 0
0010
n
1.700 1/min
2.900 1/min
3.200 1/min
Tolerance
+- 12,5 %
+- 7,5 %
+- 10,0 %
3.2 Electrical Features
Electronic function
None
Reversed polarity protection
Rectifying diode
Max. residual current at U
N
I
F
< 100 uA
Locked rotor protection
Auto restart
Locked rotor current at U
N
I
block
approx. 300 mA
Clock signal at locked rotor
t
3
/ t
4
typical: 0,6 s / 10 s
Block1: special locked rotor protection: 5 cycles t3 / t4 = 0,6 s / 0,5 s Block2: locked rotor protection t3 / t4 = 0,6 s / 10
s