Data Sheet
Product Data Sheet 3414 N
   01/31/2019  page 7 of 8 
5  Safety 
5.1  Electrical Safety 
Dielectric strength 
DIN EN 60950 (VDE 0805) and DIN EN 60335 (VDE 0700) 
A.) Type test 
Measuring conditions: After 48h of storage at 95% R.H. and 
25°C. 
No arcing or breakdown is allowed! 
All connections together to ground. 
Not applicable 
B.) Routine test 
Measuring conditions: At indoor climate. 
No arcing or breakdown is allowed! 
All connections together to ground. 
Not applicable 
Isolation resistance 
Measuring conditions: After 48h of storage at 95% R.H. and 
25°C measured with U=500 VDC for 1 min. 
RI > 10 MOhm 
Clearance / creepage distance 
1,0 mm / 1,2 mm 
Protection class 
III 
5.2  Approval Tests 
CE 
EC Declaration of Conformity 
Yes 
EAC 
Eurasian Conformity 
Yes 
UL 
Underwriters Laboratories 
Yes / UL507, Electric Fans 
VDE 
Association for Electrical, Electronic and Information 
Technologies 
Yes / Approval acc. to EN 60950 (VDE 0805) - Information 
technology equipment 
CSA 
Canadian Standards Association 
Yes / C22.2 No. 113 Fans and Ventilators 
CCC 
China Compulsory Certification 
Not applicable 
6  Reliability 
6.1  General 
Life expectancy L10 at TU = 40 °C 
70.000 h 
Life expectancy L10 at TU max. 
35.000 h 
Life expectancy L10 acc. to IPC 9591 at TU = 40 °C 
117.500 h 