Data Sheet
Product Data Sheet 4500 N
   01/31/2019  page 6 of 9 
3.2  Electrical Features 
Locked rotor protection 
Impedance 
Locked rotor current at 
3.3  Aerodynamics 
Measurement 
conditions: 
Measured with a double chamber intake rig acc. to DIN EN ISO 5801. 
Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C; 
In the intake and outlet area should not be any solid obstruction within 0,5 m. Motor shaft 
horizontal. 
The information is only valid under the specified test conditions and may be changed by the 
installation conditions. If there are deviations from the standard test conditions, the 
characteristic values must be checked under the installed conditions. 
a.) Operation condition: 
2.550 1/min at free air flow 
Frequency: 50 Hz 
Max. free-air flow (∆p = 0 / 
 = max.) 
144,0 m3/h 
Max. static pressure (∆p = max. / 
 =0) 
58 Pa 
b.) Operation condition: 
3.000 1/min at free air flow 
Frequency: 60 Hz 
Max. free-air flow (∆p = 0 / 
 = max.) 
170,0 m3/h 
Max. static pressure (∆p = max. / 
 =0) 
64 Pa 