Owner Manual

14
OPERATION INSTRUCTIONS
DANGER
CARBON MONOXIDE HAZARD
For outdoor use only. Never use inside house, or other
unventilated or enclosed areas. This heater consumes air
(oxygen). Do not use in unventilated or enclosed areas to
avoid endangering your life.
Before Turning Gas Supply ON:
1. Your heater was designed and approved for outdoor use only. Do NOT use it inside a building, garage,
or any other enclosed area.
2. Make sure surrounding areas are free of combustible materials, gasoline, and other flammable vapors
or liquids.
3. Ensure that there is no obstruction to air ventilation. Be sure all gas connections are tight and there
are no leaks.
4. Be sure the cylinder cover is clear of debris. Be sure any component removed during assembly or
servicing is replaced and fastened prior to starting.
Before Lighting:
1. Heater should be thoroughly inspected before each use, and by a qualified service person at least
annually. If relighting a hot heater, always wait at least 5 minutes.
2. Inspect the hose assembly for evidence of excessive abrasion, cuts, or wear. Suspected areas should
be leak tested. If the hose leaks, it must be replaced prior to operation. Only use the replacement hose
assembly specified by manufacturer.
Lighting:
1) Turn the control knob to the “OFF” position (Figure a).
2) Fully open LP cylinder valve.
Note: For initial start or after any cylinder change, hold Control Knob IN for
2 minutes to purge air from gas lines before proceeding.
3) Push in gas control knob and turn counterclockwise to “PILOT”
(Figure b) to light the pilot. If needed, keep depressing and turning control knob
counterclockwise until the heater lights (You should heater 2 clicking sounds).
4. After heater lights, release control knob. If you want a lower temperature, push in the control knob
and turn counterclockwise to the “LOW”.
Note: If burner fails to remain lit, all valves should be closed and a waiting period of at least 5 minutes
should pass before attempting to light.
Caution: Do not attempt to operate until you have read and understand all General Safety Information in
this manual and all assembly is complete and leak checks have been performed.
Figure 1 Figure 2
P
u
s
h
t
o
t
u
r
n
F
F
O
LOW
PILOT
HIGH
P
u
s
h
t
o
t
u
r
n
F
F
O
LOW
PILOT
HIGH