SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTIONS
1.
Crystal Fire
won’t light.
A. No LP in tank, or NG main not turned on.
Check the LP (propane) tank. You may be out of gas, or
check Natural Gas valve at main.
B. Plugged burner orice. Check the burner orice for stoppage. Remove stoppage.
2.
Low ames or
won’t stay lit.
A.
Manual shutoff valve (on/off control knob)
open or not installed between LP tank and
appliance.
Close LP tank and manual shutoff valves. Open LP tank
valve rst, THEN the manual shutoff valve.
3. Blue Flames
A.
This is a result of normal operation and
ames will begin to yellow as unit is
allowed to burn for 16-20 minutes.
Do nothing.
B.
Improper air/fuel mixture related to air
shutter position.
Close air shutter. (For LP, leave 1/4” open, Natural gas
adjust to be closed.)
4. Metallic noise A.
Noise is caused by metal expanding
and contracting as it heats up and cools
down, similar to the sound produced by a
furnace or heating duct. This noise does
not affect the operation or longevity of the
appliance.
Do nothing.
5.
Decorative
Glass cracking
or splitting
A. Heat and/or abrupt temperature changes.
This is a property of glass and may happen occasionally.
Do nothing. This is completely normal.