Owner Manual
Gas Set-Up for Natural Gas
1. With burner in place in our fire pit table or
other installation location and proper sized orifice inserted in burner neck
(see chart on p.4 for natural gas orifice sizing),
adjust air shutter to a
closed position (as shown at right, no light visible through the shutter) by
loosening the small screw on the air shutter and rotating it to a closed
position and re-tightening screw.
2. Locate the included metal flex-line hose and thread one end onto orifice
and tighten securely with two wrenches.
3. At this point you have two options for plumbing natural gas. If using a
valve assembly such as the fire table key valve kit, proceed to step 3a.
a. Attach the free end of flex hose to the top (outgoing) flare fitting of
control valve and tighten fully with two wrenches. Plumb incoming
natural gas to the incoming side of the valve using a 3/8” flare nut.
It is strongly recommended that a manual shutoff valve is placed in
the natural gas line before it reaches the fire pit’s control valve.
CHECK ENTIRE SYSTEM FOR LEAKS BEFORE OPERATING
Flare Nut
Orifice
Venturi/Air shutter
er
-OR-
Outdoor GreatRoom Co. Control panel kit
Incoming gas
Out to burner
Fire Table Key Valve
OrceFlare Nut
Out to Burner
Incoming Gas
Venturi/Air Shutter
4 GAS HOOK-UP AND INFORMATION (CONTINUED)