TM 9-2330-384-14&P
2-19. BOTTOMLOADING(PREFERREDMETHOD)(Con't).
(17)
When loading is complete, turn butterfly valve (13) 1/4 turn clockwise to close. Shut off fuel
supply.
(18)
Push vapor vent control lever (6) in cabinet to close vent.
(19)
Disconnect fuel terminal facility vapor collection hose from adapter (2). Install dust cap (1).
(20) Drain any residual fuel from fuel terminal facility's loading hose. Drain transfer hoses if
transfer hoses were used.
(21)
Disconnect fuel terminal facility loading hose and pressure fuel adapter, if adapter was
used, from front port camlock fitting. Install dust cap (12). Drain transfer hose, if transfer
hose was used. Stow transfer hose if used.
13
2
12
WARNING
Walk grounding cables backto reels when stowing grounding cables. DO NOT
let go of grounding cables until they are fully wound onto reels. Failure to
follow this warning may result in serious injury to personnel.
(22) Disconnect bonding and grounding connection (see paragraph 2-17). Stow grounding
cables and ground rod, if used.
(23) Close cabinet door and stow fire extinguishers.
2-20. TOP LOADING (ALTERNATE METHOD).
WARNING
DO NOTsmoke while loading or unloading fuel, when handling fuel containers,
or when located within 50 ft. (15.3 m) of fueling or fuel storage areas. Failure
2
to follow this warning may cause a fire and explosion, resulting in serious
injury or death to personnel.
a. Shutdown tractor engine and set tractor and semitrailer parking/emergency brakes (see TM 9-
2320-273-10 or TM 9-2320-283-10).
Change1