Specifications

TM9-2330-384-14&P
2-19. BOTTOMLOADING(PREFERREDMETHOD)(Con't).
(5)
Remove dust cap (1) and connect fuel terminal facility's vapor collection hose to adapter
(2).
NOTE
Whenfuelingat commercialfacilities,usecommercialpressurefuel
adapterassembly(seeAppendixD,AdditionalAuthorizationList).
(6)
Remove dustcap (12) and connect pressure fuel adapter (it used) and fuel terminal facility's
loading hose to front port camlock fitting. If loading hose will not reach, connect transfer
hoses stowed in curbside stowage tubes, as required.
13
2
12
WARNING
DO NOT open emergency valve when bottom loading. Automatic shut-off of
fuel flow, controlled by jet level sensor, will not function with emergency valve
open. Failure to follow this warning will result in uncontrolled fuel spillage and
danger of fire and explosion.
6 7
5
(7)
Pull vapor vent control lever (6)
in cabinet to open vent. DO
NOT pull emergency valve
control lever (5).
(8) Turn butterfly valve (13) 1/4
turn counterclockwise to open.
CAUTION
When bottom loading, pressure must
be controlled so as NOT to exceed 50
psi (345 kPa) on pressure gage (7).
Failure to follow this caution may
cause leaks in bottom loading system.
(9)
Begin to load fuel.
Change1