Specifications
TM 9-2330-384-14&P
Section V. NONELECTRICAL GAGES MAINTENANCE
Paragraph
Number
Title
Page
Number
5-7
Gage Marker Rod Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-23
5-7. GAGE MARKER ROD REPLACEMENT.
THIS TASK COVERS
a.
Removal
b.
Installation
INITIAL SETUP
Equipment Conditions:
Ref
Conditions
4-68 Tank purged.
4-73 Gage marker disk and ground wire
removed.
Tools:
l Tool kit, general mechanic’s
l Tool kit, welder’s
Personnel Required: Two
References:
l
TM 9-237
General Safety Instructions:
l When working inside tank, always provide
adequate forced air ventilation at the man-
hole opening with air directed into com-
partment where work is being performed.
l NEVER work alone inside a tank; a second
person must be stationed at the manhole
opening. The person inside the tank must
have a safety line and harness on in case of
emergency for rescue operations.
l DO NOT perform any welding procedure
unless tank is purged.
5-23