Specifications

TM 9-2330-384-14&P
4-79. SUMP DRAIN REPLACEMENT.
a.
Removal
c.
Installation
b.
Cleaning and Inspection
Equipment Conditions:
General Safety Instructions:
Ref Conditions
l Dry cleaning solvent is flammable and must
4-68 Tank purged.
not be used near open flame. Use only in a
well-ventilated area.
Materials/Parts:
l Compressed air used to dry and clear
l One locknut
passages must not exceed 30 psi
l Two lockwashers
(207 kPa).
l Drain pan
l Antiseize tape
(Item 22, Appendix E)
Tools:
l Tool kit, general mechanic’s
l Pipe wrench
4-257