4-70
Jet Level Sensor Replacement
......................................
4-215
4-71
Strainer Assembly Maintenance
.....................................
4-222
4-72
Precheck System Maintenance
......................................
4-225
4-73
Gage Marker Disk and Ground Wire Replacement
......................
4-238
4-70. JET LEVEL SENSOR REPLACEMENT.
a.
Removal of Jet Level Sensor
d.
Installation of Jet Level Sensor Tubing
b.
Installation of Jet Level Sensor
and Fittings
C.
Removal of Jet Level Sensor Tubing and
Fittings
Equipment Conditions:
Ref Conditions
4-68 Tank purged.
4-67 Manhole lid removed.
Materials/Parts:
Tag marker
(Item 21, Appendix E)
Antiseize tape
(Item 22, Appendix E)
Tools:
Tool kit, general mechanic’s
General Safety Instructions:
When working inside tank, always provide
adequate forced air ventilation at the man-
hole opening with air directed into com-
partment where work is being performed.
NEVER work alone inside a tank; a second
person must be stationed at the manhole
opening. The person inside the tank must
have a safety line and harness on in case of
emergency for rescue operations.
4-215