Specifications
TM 9-2330-384-14&P
4-69. DATA PLATE REPLACEMENT (Con't).
a.
REMOVAL
WARNING
DO NOT drill out rivets (4) if removing a data plate (3) from inside cabinet
(2). Cabinet is made of steel. Drilling a rivet from steel can produce a spark
which may cause an explosion and fire. Failure to follow this warning may
result in serious injury or death to personnel.
(1)
If removing a data plate (3) inside cabinet (2) use side cutters to remove four rivets (4). If
removing a data plate from aluminum framerail (1) at upper coupler assembly, use a hand
drill to drill out four rivets. Discard rivets.
(2) Replace data plate (3).
b. INSTALLATION
NOTE
For location of all data plates (3), refer to paragraph 1-9.
(1) Position data plate (3).
NOTE
Rivets (4) used on data plates (3) inside cabinet (2) are installed with wash-
ers (5).
(2)
Use a rivet gun to install data plate (3) with four new rivets (4).
4-214