Specifications
TM9-2330-384-14&P
4-53. FIREEXTINGUISHERMOUNTINGBRACKETMAINTENANCE.
WARNING
DrycleaningsolventP-D-680istoxicandflammable.Alwayswearprotective
goggles,faceshield,andgloves,anduseonlyinawell-ventilatedarea.Avoid
contactwithskin,eyes,andclothesandDONOTbreathevapors.DONOTuse
nearopenflameor excessiveheat. Thesolvent'sflashpointis 100*F-138*F
(38*C-59*C).Ifyou becomedizzywhileusingcleaningsolvent,immediately
get fresh air andmedical help.Ifsolventcontactseyes,immediatelywashyour
eyeswithwaterandgetmedicalaid.
(2)
Use dry cleaning solvent to clean surfaces of fire extinguisher mounting bracket (3) that come in
contact with frame (4). Allow to dry thoroughly.
c. INSTALLATION
CAUTION
To protect against corrosion and distribution of components, mylar tape must
be applied to surfaces of fire extinguisher mounting bracket (3) that come in
contact with frame (4).
(1)
Apply suitable width of mylar tape to all surfaces of fire extinguisher mounting bracket (3) that come
in contact with frame (4). Pierce holes in mylar tape at mounting bolt holes to prevent water
accumulation.
(2)
Install four new grommets (2) in fire extinguisher mounting bracket (3).
(3)
Install fire extinguisher mounting bracket (3) on frame (4) with four screws (1), washers (6), and new
locknuts (5).
(4)
Trim excess mylar tape.
FOLLOW-ON TASKS:
Install fire extinguisher.
Change1
4-169