Specifications

TM9-2330-384-14&P
4-53. FIREEXTINGUISHERMOUNTINGBRACKETMAINTENANCE.
I
THISTASKCOVER
a. Removal
c. Installation
b. Cleaning
Equipment Conditions:
Materials/Parts:
Ref
Conditions
- Four grommets
---
Fire extinguisher removed.
- Four locknuts
- Dry cleaning solvent
(Item 10, Appendix E)
Tools:
- Mylar tape
(Item 24, Appendix E)
Tool kit, general mechanic's
General Safety Instructions:
Dry cleaning solvent is flammable and must not be
used near open flame. Use only in a well-venti-
lated area.
a. REMOVAL
(1)
Remove four locknuts (5), screws
3
(1), and washers (6) at fire
2
extinguisher mounting bracket (3).
Discard locknuts.
(2)
Remove fire extinguisher mounting
10
bracket (3) from frame (4).
(3)
Remove four grommets (2) from
0
fireextinguisher mounting bracket
(3). Discard grommets.
b. CLEANING
(1)
Remove all traces of old mylar tape
6
5
from mounting surfaces of fire
extinguisher mounting bracket (3)
and frame (4).
4-168
Change1