Specifications
TM 9-2330-384-14&P
4-28. TRIPLE CLEARANCE LIGHT ASSEMBLY REPLACEMENT.
a.
Removal b.
installation
Equipment Conditions:
Ref Conditions
2-14
Intervehicular electrical cable discon-
nected from semitrailer.
Tools:
l Tool kit, general mechanic’s
l Wire terminal kit
Materials/Parts:
One connector
Corrosion preventive compound (Item 7,
Appendix E)
General Safety Instructions:
l When performing electrical maintenance,
ALWAYS disconnect intervehicular electri-
cal cable from semitrailer.
a. REMOVAL
WARNING
When performing electrical maintenance, ALWAYS disconnect inter-
vehicular electrical cable from semitrailer. Failure to follow this warning
may create a spark and explosion,
resulting in serious injury or death to
personnel.
4-79