Specifications

TM 9-2330-384-14&P
4-25. SIDE CLEARANCE AND MARKER LIGHT MAINTENANCE.
a.
b.
Button Contact Repair
C.
Installation
Removal
Equipment Conditions:
Ref Conditions
2-14
Intervehicular electrical cable discon-
nected from semitrailer.
Tools:
Materials/Parts:
One button contact
One connector
One gasket
Corrosion preventive compound (Item 7,
Appendix E)
Tool kit, general mechanic’s
Wire terminal kit
General Safety Instructions:
When performing electrical maintenance,
ALWAYS disconnect intervehicular electri-
cal cable from semitrailer.
a. BUTTON CONTACT REPAIR
WARNING
When performing electrical maintenance, ALWAYS disconnect inter-
vehicular electrical cable from semitrailer. Failure to follow this warning
may create a spark and explosion, resulting In serious injury or death to
personnel.
4-69