Specifications

TM 9-2330-384-14&P
4.22. CONVOY WARNING LIGHT WIRING MAINTENANCE (Con't).
d. INSTALLATION OF CONDULET AND RECEPTACLE
WARNING
When performing electrical maintenance, ALWAYS disconnect Inter-
vehicular electrical cable from semitrailer. Failure to follow this warning
may create a spark and explosion, resulting In serious Injury or death to
personnel.
NOTE
9 Ensure that all connections are made to clean, uncorroded surfaces.
Cost all wire connections with corrosion preventive compound before
they are made.
a To Install receptacle (14), perform steps 4 through 7.
(1)
install straight adapter (21) to condulet (5).
(2)
install condulet (5) to rear dam (6) with two screws (15), four washers (13), and two new
locknuts (12).
(3)
Thread brown and blue wires (20 and 17) through straight adapter (21) into condulet (5).
Connect conduit (23) to straight adapter and tighten nut (22).
(4)
Install receptacle (14) to condulet (5).
(5)
Connect brown wire (20) to white receptacle wire (16) with new connector (19). Connect blue
wire (17) to black receptacle wire (18) with new connector. Crimp connectors.
(6)
Install new gasket to cover (11). Install cover and tighten two captive screws (10).
(7)
If removed, use a rivet gun to install retaining chain (9) to rear dam (6) with rivet (8). Install
cap (7) on receptacle (14).
4-59