External Humidistat Option
The Free Star has the option of using an external humidistat remotely
mounted within a room, where available.
In the control box there is a connector that can be wired to, which will
enable the use of an external humidistat. The following steps should be
carried out to enable correct operation of the external humidistat.
Locate the control box and remove the cover, keeping screws for re-
attachment
Locate the connector within the control box and remove the plug from the
socket
Dismantle the plug and remove the link wire from terminals 2 & 3
Wire remote humidistat to terminals 1 & 3, ensuring wires pass through
the plug back shell
Re-assemble the plug and refit to the socket on the control box
The Free Star internal humidistat will now be by-passed and the external