Specifications
Page 68 of 89
Rejection Goal - On the second page of the Array Assistant for Otto, the ‘Coverage
Goal’ and ‘SPL Requirement’ sliders function as they do with all other arrays. A third
slider has been added which allows the user to input a desired ‘Rejection Goal’. The
‘Rejection Goal’ slider allows the user to choose ‘Max SPL’, ‘Max Rejection’ or points in
between to achieve an appropriate balance between rejection and SPL depending on
the application.
Max SPL - Selecting ‘Max SPL’ will configure Otto to provide the maximum possible
SPL over the user defined audience surfaces, or defined coverage areas in the
Resolution model.
Max Rejection - Selecting ‘Max Rejection’ will configure Otto to reject energy
outside of the user defined audience surfaces, or defined coverage areas in the
Resolution model. Maximum Rejection by default is opposite the primary coverage
areas.