measurements in the future. Total time to complete the process for all transducers in
an Anya module will be about 5 minutes.
*Note: The noise burst stimulus will sound like a “popping” noise due to the extremely
short duration. This is normal and should not be interpreted as any fault in the system.
Measure
Measure allows you to perform diagnostics to check the health of the Anya module.
To start the diagnostics function, check the Sweep box for each transducer you wish to
measure, click the Measure button. Anya will perform the same measurements as the
Calibrate function and compare the average of the three measurements with the
reference stored in the internal memory. Resolution 2 will then display a Pass or Fail
result for each transducer.
Cancel
Clicking Cancel during a Calibrate or Measurement routine will stop the measurement.
4.8.8 Adaptive Healing
In the event that an Adaptive Module which is part of an array is unassigned, or goes
offline, Resolution gives the user the ability to heal around those missing modules when
the Upload Array Parameters box is selected.
When the user opts to ‘exclude these modules and recalculate’, Resolution will generate
a new acoustical model, taking into account the missing module and optimizing the
sound system given the available online modules. Once an option is chosen and the
network is refreshed, the dialogue will not appear until the modules in the system
unassigned, then reassigned accordingly.