Specifications
Page 28 of 89
number of modules included in the system. These switches do not include a DHCP server.
Each Anya module includes an Audinate Dante Network Interface Card (NIC). If the
module does not detect a DHCP server on the network, then all modules will default to
the Private Network range of IP addresses and each module will select a unique IP
address from the following ranges:
Primary Network (in redundant networks) and non-redundant networks
o IP Address Range: 169.254.###.###
o Subnet Mask: 255.255.0.0
Secondary Network (in redundant networks only)
o IP Address Range 172.31.###.###
o Subnet Mask: 255.255.0.0
The computer running Resolution 2 connected to the network can automatically
select an IP address in the primary network range if no DHCP server is detected on
the network, but it generally is a best practice to manually assign your computer IP
address and Subnet Mask in the Private Network range to speed up the discovery
process. A computer on the Secondary network must be manually assigned an IP
address in the range 172.31.###.###.
*Note: All Adaptive modules and the control computer must be connected to the
same network!
All Primary Ethernet ports on every Adaptive module must be connected to the
same Primary network on the switches and Secondary ports to Secondary
network on the switches.
All switches must be linked Primary to Primary, Secondary to Secondary.
Any Dante source device such as mixing consoles must also be connected to
the same Primary and Secondary networks.