Specifications

EAW Smaart 6 Operation Manual Applications
78
Figure 4-8 Speaker/amp measurement setup
4.3.1 Adjust Signal Levels
1. Position the measurement microphone about 1 meter (3.3 ft) from the loud-
speaker. As the mic’s distance from the loudspeaker increases, it becomes more
difficult to discern the loudspeaker’s direct sound from the room’s reflections.
2. Click the Spectrum button to display the standard Spectrograph (top) and RTA
(bottom) graphs.
3. Click the Start button to turn the analyzer on.
4. Activate the internal signal generator and adjust its level until the loudspeaker
is significantly louder than the room’s ambient noise. Start with a low amplifier
gain and slowly increase it to avoid damaging your hearing or equipment.
5. Adjust the input levels on the sound card and mic preamp to achieve a proper
input level (see Figure 1-2).
6. For best results, match the reference and measurement input levels as closely
as possible (see page 76).
Amplifier
Measurement
Microphone
Microphone
Preamp
Loudspeaker
Measurement
Signal
Reference Signal
Computer
Line Out