Specifications

EAW Smaart 6 Operation Manual Applications
77
Figure 4-7 Sample measurement of an analog parametric EQ filter
4.3 Measuring a Loudspeaker
This example uses IR Analysis mode and the real-time Frequency Response display to
measure a loudspeaker in a room.
The following components are required:
Amplifier and loudspeaker
Measurement microphone with flat frequency response (preamp/phantom
power supply if the mic requires it)
Cables and adapters to make the required connections, including one Y-cable
Connect the components as shown Figure 4-8.
The output of the signal source (in this case, the computer output channel des-
ignated as Main Out Smaart) drives the power amplifier and loudspeaker, as
well as the Reference Input (Ref In) channel for Smaart.
A measurement microphone is routed to Smaart’s Measurement Input (Meas
In). Smaart’s audio input and output devices and channel assignments are set
from the Audio I/O tab of the Options dialog (see page 98).