Specifications
EAW Smaart 6 Operation Manual Getting Started
20
1.4.9 Internal Delay Control
The Delay control (Figure 1-8) provides access to Smaart 6’s internal signal delay. The
internal delay can provide up to 750 ms of delay (in 0.01 ms increments) for one of the
two input signals, intended primarily to provide signal alignment for Frequency Response
measurements. The delay selected and corresponding distance are displayed on the Delay
control. To alter delay times by the increments specified in the Delay tab, use the up and
down arrow buttons to the right of the readout field. Or, click the Delay readout and enter
the desired delay time directly.
Auto Delay Locator Buttons
The Auto Sm and Auto Lg buttons (Figure 1-8) activate Smaart 6’s Automatic Delay
Locator using the small or large time window preset, respectively. See Automatic Delay
Locator on page 55 for more details.
1.4.10 Signal Level/SPL Display and Input Level Meters
Figure 1-10 Signal level, SPL, and input meters
The Signal Level/SPL Display provides a numeric readout of the overall signal level
for the selected SPL Source channel (see Audio I/O on page 98) and can be calibrated
to provide SPL readings.
The input level meters display the levels of the two input signals relative to the maximum
input voltage (regarded as 0 dB) for the A/D converters on the selected input device.
Each meter includes a clip indicator that lights if the input signal level exceeds the A/D
converter’s maximum input voltage. Click the Mea Sig and Ref Sig to show/hide the
corresponding signal on the RTA display.