5.3.6 Zoom
Figure 5-8 Zoom tab in Options dialog
Choose Options
-
>Zoom or press Alt+z to display the Zoom tab to configure four zoom
settings.
Use Nyquist: Check this box to automatically set the Max frequency field to the highest
frequency obtainable with the selected sampling rate (Nyquist Frequency = SR/2). The
Max field in Figure 5-8 is set to 24 kHz (SR = 48 kHz) but is gray and inactive because
this box is checked.
Min: Set the desired minimum frequency for each zoom.
Max: Set the desired maximum frequency for each zoom.
Click Apply or OK to apply the new settings. Choose Zoom 1-Zoom 4 by pressing the
1-4 keyboard keys, respectively.
5.3.7 Instantaneous
Choose Options->Instantaneous or press the Ctrl+I keys to toggle the Avg parameter
(Spectrum and Freq. Resp.) from its current setting to Inst. Note that the Avg list is de-