CLA6 CLA4 CLA2 Column Loudspeakers INSTRUCTION MANUAL
1. SAFETY INSTRUCTIONS CAUTION AVIS RISK OF ELECTRIC SHOCK • DO NOT OPEN RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR 1. 2. 3. 4. 5. 6. 7. Read Instructions CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK Keep these Instructions DO NOT REMOVE COVER (OR BACK) NO USER-SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED PERSONNEL Heed all Warnings ATTENTION: POUR EVITER LES RISQUES DE CHOC ELECTRIQUE, NE PAS ENLEVER LE COUVERCLE. AUCUN ENTRETIEN DE PIECES INTERIEURES PAR L'USAGER.
TABLE OF CONTENTS 1. SAFETY INSTRUCTIONS........................................................ 2 2. INTRODUCTION....................................................................... 3 3. INSTALLATION ........................................................................ 4 4. CONNECTIONS........................................................................ 5 5. SPECIFICATIONS..................................................................... 6 6. SERVICE INFORMATION ................................
3. INSTALLATION The two support brackets provided can be used for installing the sound column on the wall or ceiling. Use the supplied bolts, plain washers and split lock washers to bolt the brackets to the loudspeakers. WARNING: Make sure that the loudspeaker is installed in a stable and secure way in order to avoid any conditions that may be dangerous for persons or structures: • Check to make sure that the support surface (e.g., wall, etc.
4. CONNECTIONS WARNING: To prevent the risk of electric shock, do not connect the loudspeaker or adjust the power selector with the amplifier switched on. The loudspeaker is designed to be connected to constant-voltage audio lines at 70 V or 100 V. 1. The white wire of the loudspeaker connects to the positive amplifier output, the black loudspeaker wire connects to the negative amplifier output. 2. Use a suitable tool to crimp the two supplied wires to the ends of your audio line conductors.
CLA2 20 W 3” x 2 2” x 1 87 dB 100 dB 150 Hz-20 kHz 190˚/120˚ CLA4 30 W 3” x 3 2” x 1 88 dB 103 dB 140 Hz-20 kHz 195˚/105˚ CLA6 40 W 3” x 4 2” x 1 90 dB 106 dB 140 Hz-20 kHz 205˚/140˚ 400 Hz 125˚/30˚ 400 Hz 105˚/30˚ 400 Hz 85˚/45 ˚ 11.97”/304 mm 3.74”/95 mm 3.7”/94 mm 3.97 lbs/1.8 kg 2 L-brackets 15.24”/387 mm 3.74”/95 mm 3.7”/94 mm 5.07 lbs/2.3 kg 2 L-brackets 18.46”/469 mm 3.74”/95 mm 3.7”/94 mm 6.39 lbs/2.9 kg 2 L-brackets 3.82 " 97.
6. SERVICE INFORMATION In the event that your CLA loudspeaker should require servicing, please follow these instructions: 1. Call EAW Commercial Tech Support at 1-888-337-7404, 7 am to 5 pm PST (Monday-Friday), to verify the problem and obtain a Return Authorization (RA) Number. Be sure to have the serial number of the unit when you call. You must have a Return Authorization Number in order to obtain warranty service at the factory or at an authorized service center.
EAW Commercial | One Main Street | Whitinsville, MA 01588 USA TEL toll free within US/Canada 888.337.7404 | TEL outside US 425.892.6503 | FAX 425.485.1152 www.eawcommercial.com © 2004 LOUD Technologies Inc. All Rights Reserved. EAW Commercial is a registered trademark of LOUD Technologies Inc.