Multi-Purpose Control Application
Protections (Control Keypad: Menu M1
G1.7)
Table 6-24: Protections — G1.7
Code Parameter Min. Max. Unit Default Cust ID Note
P1.7.1 Ref Fault Resp 0 5 0 700 0 = No Action
1 = Warning
2 = Warn:Stop
3 = Warn:PrevFre
4 = Warn:PresetF
5 = Fault
6 = Fault,Coast
P1.7.2 Ref Fault Freq. 0.00 Par. 1.1.2 Hz 0.00 728
P1.7.3 Response to
external fault
0 3 2 701 0 = No response
1 = Warning
2 = Fault.stop acc. to 1.4.7
3 = Fault.stop by coasting
P1.7.4 Input phase
supervision
0 3 3 730
P1.7.5 Response to
undervoltage fault
1 3 0 727
P1.7.6 Output phase
supervision
0 3 2 702
P1.7.7 Earth fault
protection
0 3 2 703
P1.7.8 Thermal
protection of the
motor
0 3 2 704
P1.7.9 Motor ambient
temperature factor
-100.0 100.0 % 0.0 705
P1.7.10 Motor cooling
factor at zero
speed
0.0 150.0 % 40.0 706
P1.7.11 Motor thermal
time constant
1 200 min 40 707
P1.7.12 Motor duty cycle 0 100 % 100 708
P1.7.13 Stall protection 0 3 0 709 0 = No response
1 = Warning
2 = Fault.stop acc. to 1.4.7
3 = Fault.stop by coasting
P1.7.14 Stall current 0.00 I
nMotor
x 2 A I
L
710
P1.7.15 Stall time limit 1.00 120.00 s 15.00 711