Firmware Manual

9000X AF Drives
8-78 For more information visit: www.eaton.com
MN04004001E
August 2010
Description of Parameters
Table 8-14: Selectable Wake-Up Functions
Parameter
Value Function Limit Description
0 Wake-up happens
when actual value
goes below the limit
The limit defined with
ID1018 is in percent of
the maximum actual
value
1 Wake-up happens
when actual value
exceeds the limit
The limit defined with
ID1018 is in percent of
the maximum actual
value
2 Wake-up happens
when actual value
goes below the limit
The limit defined with
ID1018 is in percent of
the current value of the
reference signal
3 Wake-up happens
when actual value
exceeds the limit
The limit defined with
ID1018 is in percent of
the current value of the
reference signal
Actual
Value Signal
100%
Time
ID1018
=
30%
Start
Stop
ID1018
=
60%
Actual
Value Signal
100%
Time
Start
Stop
ID1018
=
60%
Limit
=
60%* Reference
=
30%
Reference
=
50%
Actual
Value Signal
100%
Time
Start
Stop
ID1018
=
140%
Limit
=
140%* Reference
=
70%
Reference
=
50%
Actual
Value Signal
100%
Time
Start
Stop