Firmware Manual

9000X AF Drives
MN04004001E
For more information visit: www.eaton.com
8-49
August 2010
Description of Parameters
Figure 8-40: Digital Outputs 1 and 2, On- and Off-Delays
481 Analog output 3 inversion 67 (P1.3.7.4, P1.3.5.4)
See ID309.
482 Analog output 3 minimum 67 (P1.3.7.5, P1.3.5.5)
See ID310.
483 Analog output 3 scaling 67 (P1.3.7.6, P1.3.5.6)
See ID311.
484 Analog output 3 offset 67 (P1.3.7.7, P1.3.5.7)
See ID375.
485 Torque limit 6 (P1.2.6.5)
See ID399 for the selections.
486
Digital output 1 signal
selection 6
6 (P1.3.1.1)
Connect the delayed DO1 signal to the digital output of your choice with this
parameter. For more information about the TTF programming method, see Page 6-3.
487 Digital output 1 on-delay 6 (P1.3.1.3)
488 Digital output 1 off-delay 6 (P1.3.1.4)
With these parameters you can set on- and off-delays for digital outputs.
489
Digital output 2 signal selection 6 (P1.3.2.1)
See ID486.
490 Digital output 2 function 6 (P1.3.2.2)
See ID312.
491 Digital output 2 on-delay 6 (P1.3.2.3)
See ID487.
DO1 or DO2 Output
Signal Programmed
to Digital Output
ON-Delay
OFF-Delay