437
External fault or warning 67 (P1.3.3.6, P1.3.1.6)
Fault or warning depending on ID701.
438
Reference fault or warning 67 (P1.3.3.7, P1.3.1.7)
Fault or warning depending on ID700.
439
Overtemperature warning 67 (P1.3.3.8, P1.3.1.8)
The heatsink temperature exceeds +70°C.
440
Reverse 67 (P1.3.3.9, P1.3.1.9)
The Reverse command has been selected.
441
Unrequested direction 67 (P1.3.3.10, P1.3.1.10)
Motor rotation direction is different from the requested one.
442
At speed 67 (P1.3.3.11, P1.3.1.11)
The output frequency has reached the set reference.
443
Jogging speed 67 (P1.3.3.12, P1.3.1.12)
Jogging speed selected.
444
External control place 67 (P1.3.3.13, P1.3.1.13)
Control from I/O terminal selected (Menu M2; ID125).
445
External brake control 67 (P1.3.3.14, P1.3.1.14)
External brake ON/OFF control with programmable delay.
446
External brake control, inverted 67 (P1.3.3.15, P1.3.1.15)
External brake ON/OFF control; Output active when brake control is OFF.
447
Output frequency limit 1
supervision
67 (P1.3.3.16, P1.3.1.16)
The output frequency is outside the set supervision low limit/high limit (see ID315
and ID316).
448
Output frequency limit 2
supervision
67 (P1.3.3.17, P1.3.1.17)
The output frequency is outside the set supervision low limit/high limit (see ID346
and ID347).