Firmware Manual
9000X AF Drives
8-44 For more information visit: www.eaton.com
MN04004001E
August 2010
Description of Parameters
414
Fault reset 67 (P1.2.7.10, P1.2.6.13)
Contact closed: All faults are reset.
415
Acceleration/Deceleration
prohibited
67 (P1.2.7.14, P1.2.6.14)
Contact closed: No acceleration or deceleration possible until the contact is opened.
416
DC-braking 67 (P1.2.7.15, P1.2.6.15)
Contact closed: In STOP mode, the DC braking operates until the contact is opened.
417
Motor potentiometer DOWN 67 (P1.2.7.8, P1.2.6.16)
Contact closed: Motor potentiometer reference DECREASES until the contact is
opened.
418
Motor potentiometer UP 67 (P1.2.7.9, P1.2.6.17)
Contact closed: Motor potentiometer reference INCREASES until the contact is
opened.
419
Preset speed 1 6 (P1.2.7.5)
420
Preset speed 2 6 (P1.2.7.6)
421
Preset speed 3 6 (P1.2.7.7)
Parameter values are automatically limited between the minimum and maximum
frequencies (ID101 and ID102).
422
AI1/AI2 selection 6 (P1.2.7.17)
This parameter is used to select either AI1 or AI2 signal as the frequency reference.
423
Start A signal 7 (P1.2.6.1)
Start command from control place A.
Default programming: A.1
424
Start B signal 7 (P1.2.6.2)
Start command from control place B.
Default programming: A.4
425
Control place A/B selection 7 (P1.2.6.3)
Contact open: Control place A
Contact closed: Control place B
Default programming: A.6