Description of Parameters
Figure 8-26: Scaling of Max. Motor Current
Figure 8-27: Reduction of DC Braking Current
362 Free analog input, function 34 (P1.2.21, P1.2.18)
This parameter is used for selecting a function for the free analog input signal:
0 Function is not in use
1 Reduces motor current limit (ID107)
This signal will adjust the maximum motor current between 0 and maximum limit set
with ID107. See Figure 8-26.
2 Reduces DC braking current
DC braking current can be reduced with the free analog input signal
between current 0.4 x I
H
and the current set with ID507. See Figure 8-27.
Torque Limit
Signal Range
100%
ID107
0 V
0 mA
4 mA
Custom
10 V
20 mA
20 mA
Custom
Analog
Input
DC-Braking
Current
Signal Range
100%
ID507
0
Free Analog
Input
0.15xI
L