Firmware Manual

9000X AF Drives
MN04004001E
For more information visit: www.eaton.com
8-11
August 2010
Description of Parameters
Figure 8-6: Start Forward/Start Reverse
Figure 8-7: Start, Stop and Reverse
The first selected direction has the highest priority.
When the DIN1 contact opens the direction of rotation starts to change.
If Start forward (DIN1) and Start reverse (DIN2) signals are active
simultaneously the Start forward signal (DIN1) has priority.
1 DIN1: closed contact = start — open contact = stop
DIN2: closed contact = reverse — open contact = forward, see Figure 8-7.
1
FWD
REV
DIN1
DIN2
t
Output
Frequency
Stop Function
(ID506) = Coasting
2 3
FWD
REV
DIN1
DIN2
Output
Frequency
Stop Function
(ID506) = Coasting
t